System
IR radiation + Forced convection and ventilation
Operating temperature range
Room temp. +10 ~ 360℃
GB standard Temp. fluctuation
±0.2℃ (at 360℃, IR heater off)
Temperature deviation
±5℃ (at 360℃, IR heater off)
Temp. adjustment accuracy
±0.2℃ (at 360℃, IR heater off)
Temp. distribution accuracy
±3℃ (at 360℃, IR heater off)
Max. temp. reaching time
100 min (from room temperature to 360℃, IR heater off)
Main body heater
Fin-type stainless steel heating tube 3.75kw
Motor · fan
Capacitor-type motor 20w + axial flow fan
Sensors
K-type thermocouple double probe × 1 (for main body temperature controller and overheating preventer),K-type thermocouple × 2 (for IR heater, centrally embedded in IR heater)
Cable port
I.D. 30 mm, located at the back
Other additional functions
Exhaust vent (manual type)
Controllers Control method
PID control (main body)
Operating functions
Fixed temp. operation, rapid automatic stop, automatic stop, automatic start
Additional functions
Deviation correction function, key lock function, power failure compensation function, door switch detection
Safety device
Leakage circuit breaker Leakage, short circuit, and overcurrent protection
Self-diagnostic function
Temperature sensor abnormality, heater disconnection, SSR short circuit, automatic overheating prevention function
Internal dimensions (width × depth × height mm)
600×600×600
Effective dimensions (width × depth × height mm)
600×600×200
External dimensions (width x depth x height mm)
1200×780×1000
IR heater upper and lower spacing
200mm
Power Source
3-phase 380V 50/60Hz 18A
Accessories
Shelf Stainless steel wire mesh plate1 pcs,Supports 2 pcs